The FTU-R200 series are multi-functional Recloser controllers which provide fault protection, status monitoring and control, metering, event/fault recording and various communication protocols.

Application

Automatic Circuit Recloser(ACR) is mostly used in overhead power distribution line to reduce power outage area when a fault happens in the line and to increase the continuity of a supply of electric power through reclosing tries for temporary fault. Nowadays, various kind of distributed generations is being connected to the distribution line. Therefore, the distribution network is no longer radial system and needs more intelligent protection function such as directional or anti-islanding protection.

FTU provides all needed protection functions for various kind of faults, status monitoring and control of the ACR, measurements of electric quantities of the line, power quality monitoring, event and disturbance waveform recording, and communication interface for SCADA or distribution automation system.

ACR is occasionally used as a feeder circuit breaker in distribution substation. IEC61850(Ed.2) protocol is also included for substation automation.

We support customization of control for satisfying with different requirements of electric utilities.

Features

IEC, ANSI/IEEE overcurrent curves, traditional Recloser curves, customized curves

Sensitive earth fault, broken conductor, intermittent fault protection

Fault location with distance, fault type, fault resistance

4-quadrant power and energy metering, power quality monitoring

Demand/load profile, event recording and fault waveform recording with COMTRADE format

Graphical programmable logic (IEC61113-3) with EasyLogic software

Various communication protocol: DNP3.0, DNP3.0 over TCP/IP, IEC60870-5-101/104, IEC61850

Backup battery charger & test function

Type tested in accordance with IEC61000-4, IEC60255, ANSI/IEEE C37.90

  • FTU-R200

    Standard Control for Automatic Circuit Recloser

  • FTU-R200i

    Advanced Control for Automatic Circuit Recloser

    Support IEC 61850 Protocol, Two LAN Ports or Two Fiber optic

  • FTU-R200S

    Control for Single Phase Automatic Circuit Recloser

  • FTU-R300

    Intelligent Control for Automatic Circuit Recloser

    Equipped with Color Touch LCD, Wifi, Bluetooth

Catalog

Technical Data

  • Protection

    Phase/Earth/Negative Over Current , 2nd Harmonic Restraint, Trip & Reclosing, Sensitive Earth Fault (SEF), Intermittent Earth Fault(IEF), Broken Conductor, Open Line Detection, Directional Tripping/Blocking, Under Voltage, Over Voltage/Ground Over Voltage, Under Frequency, Over Frequency, Synchronism Check, Hot Line Fault Detection, Loop Automation Scheme, Fault Location, Sectionalizer, 4 Setting Groups

  • Metering

    Current, Voltage, Power, Power Factor, Frequency, Energy, Harmonics, Demand, Internal Temperature

  • Status Monitoring

    10 Contact Inputs*, Power Supply Status (External Power, Battery Low And Fail, Charger Fail), Interrupter Duty Monitor, Analog Alarm, 24 LEDs For Function Indicators*

  • Control

    Switch Control: SBO (Select Before Operate – OPEN/CLOSE), Password Protection, Local / Remote, Hot Line Tag
    4 Contact Relay Outputs*, 2 High-speed Outputs, Reset Annunciator, Battery Test,
    Protection Function Blocking: Reclosing, Protection(all), Earth Protection(Earth and SEF)*, 12 Programmable Buttons*

  • Recording

    Event recording with 1ms time-stamp:
    I/O changed events (1023), Functional operating events (20,000)*, System related events (255), Communication events (255), Fault current (1,023), PQM events (255), Demand profile: current, voltage and power (6,143) Daily maximum current, voltage and power (1,023), Energy & Peak Demand Profile (63)

    Waveform Recording:
    8 Fault waveforms, 6 PQM waveforms, 1 Manual trigger waveform, 128 samples/cycle, 40 cycles, Saving COMTRADE File format

  • Power Quality Monitoring

    Voltage Unbalance*, Current Unbalance*, Sag, Swell, Voltage THD Alarm, Current THD Alarm, Interruption

  • Communication

    USB or RS232C(Maintenance Port), RS232C(Modem Control Supports), RS232C/485, Ethernet Port 10/100 Base-T, Fiber Optic*, PRP/HSR scheme (Parallel Redundancy Protocol)/(High Availability Seamless Redundancy)*

  • Protocol

    MODBUS Serial/TCP, DNP3.0, DNP3.0 over TCP/IP with Secure Authentication v2/v5*, IEC 60870-5-101, 104

    IEC 61850 Edition 2*, SNTP (Simple Network Time Protocol), TFTP (Trivial File Transfer Protocol), HTTP (Web server), GSM protocol (SMS)

* The detailed specification is different according to the model.