Substation IED

Substation IED

The PAC-X series are designed to provide total solution of protection, control, monitoring and metering for power system application including power substation, power stations, and other industrial plants. With proven protection algorithms, flexible I/O, built-in monitoring and high accuracy metering capability with modern communication technologies, the PAC-X series provide reliable, secure, efficient and cost effective solution to the customer.

Application

Protection, control, monitoring and supervision of power facilities in generation, transmission, distribution, substation and industrial systems

Utility substation and automation

Digital fault recording and Sequence of Event (SOE) recording

Comprehensive protection & control scheme with complete diagnostic and automation capabilities

Features

Color Graphic LCD HMI (5.6”) as the touch screen*

Various TC curves as IEC, ANSI/IEEE, etc.

Easy-to-use Windows based Engineering tool PACManager™ for logic configuration and maintenance

Simple and intuitive logic configuration screen to implement various functions

Multiple Communication Protocol - IEC61850, DNP3.0 over TCP, Modbus RTU/TCP

Watchdog Timer & Self-Diagnosis

Type tested based on IEC standards

  • PAC-XF100

    Feeder Protection IED

  • PAC-XG100

    Generator/Transformer protection IED

  • PAC-NX100

    Feeder and Motor protection IED with compact design

Technical Data

  • Protection and Control

    Fast, segregated line current differential & distance protection functionality in one device

    Phase distance (5 zones) with independent settings for compensation

    Single-pole tripping, breaker-and-a-half with independent current source support

    Comprehensive generator protection with 100% stator and field ground fault detection

    Protection and control functionality in one box, reducing the number of devices

    Integrated large, MIMIC diagram and graphic display, for real-time visualization and control of the protected bay

    SBO (Select Before Operating) & CBO (Check Before Operating)

  • Monitoring and recording

    Fault recording capabilities, configurable & extended waveform capture and data logger

    SOE (Sequence of Event)

    Breaker condition monitoring

    Metering: current, voltage, power factor, frequency, voltage & current harmonics, energy, demand, phasors, etc.

  • Auxiliary functions

    Programmable Logic Control

    Supervision: CT/PT input, PT Fuse Fail, TCS (Trip Circuit Supervision)

    Self-Diagnosis

    Direct CB Control

  • Communication

    USB or RS232C(Maintenance Port), RS232C/485 port, Ethernet Port 10/100 Base, 2 Fiber optics*

  • Protocol

    Modbus RTU, IEC60870-5-103, DNP3.0, Modbus TCP, DNP over TCP, IEC61850*

  • Power Supply

    110~240VAC or 24~110VDC

* The detailed specification is different according to the model.